Non avevi tensione.
Nei file .err sono registrati solo gli errori (se presenti) di comunicazione.
Nei file .err sono registrati solo gli errori (se presenti) di comunicazione.
C:\aurora See http://www.curtronics.com/Solar/ for Solar Site example Usage: aurora [Options] Device v1.7.4 Options: -A, --last-alarms Get last four alarms (once displayed FIFO queue is cleared) -b, --verbose Verbose mode. For maximum effectiveness should be the first option on the command line -C, --calc-value=Calculate monetary value using * kWh. ":$" is optional and if included the character(s) represented by the "$" will be used to denote monetary type in the output. Defaults to "$" -c, --columnize Output data in columns --> for -d, -e, -D, -E, -t, & -T options only will disable any other options -- if value ends with an "*" reporting of that item may not be in inverters firmware -d , --get-dsp= Get DSP data. indicates string to get data for. 0 indicates both, 1 for only string 1, 2 for only string 2. is required for short option and is optional for long option and if omitted for long option then data for both input strings will be retrieved. -D, --get-dsp-extended Get more DSP data -e, --get-energy Get Cumulated Energy readings -E, --get-dsp-3phase Get 3-Phase DSP data -f, --firmware-ver Query for Firmware Version string -g, --mfg-date Query for Inverter Manufacturing Date -h, --help This text -i, --get-count Display Inverter Time Counters -j, --get-joules Display Energy cumulated in the last 10 seconds -k , --daily-kwh= Get past daily kWh for days (1-366) is required for short option and optional for long option and if omitted for long option then all 366 days or as many that are found will be displayed -L , --adjust-time= Automatically adjust the inverter time if it differs from the computer time. If is 0 (zero) do a Daylight Savings Time check. If is >= 1 change the inverter time if it differs by or more seconds. See the README for more information and constraints -l , --delay= Serial port timeout in for read. in 1/10ths seconds Default is 1 (0.1 sec) -m, --get-conf Query for Inverter System Configuration -n, --serial-number Query for Inverter Serial Number -o, --output-file= Append data to file (Created if nonexistant) -P , --comm-pause= Wait us between sending commands to inverter (1-1000000) -p, --part-number Query for Inverter Part Number -q , --energy-sent= Get past energy delivered to the grid ** Experimental ** in 10 second intervals for minutes (1-1440). is optional for long option and if omitted all data, ~24 hours worth will be reported. It is suggested the -Y option be used with this due to the extensive length of time this could take. See the README file for important information on this option -R , --read-timeout= Timeout value when reading data from the Inverter (ms) -r, --calc-grid-power Calc Grid power using Grid Voltage * Grid Current, instead of reporting the Inverter's value. --> for -d option only, ignored when used with -c option (Inverter typically reports a lower value. This affects Inverter conversion efficiency value.) -S, --set-time Set Inverter Date/Time to system time -s, --get-state Get Inverter State -T, --get-loctime Display computer Date/Time -t, --get-invtime Display Inverter Date/Time -V, --version Aurora communications program version -v, --inv-version Query for Version string -U , --read-pause= Pause milli-seconds after sending command to inverter before reading response from inverter (1-10000) -u, --rpt-read-pause Report when/that pausing before read -W, --swap-endian Swap Endianness -w, --lock-wait Seconds to wait to lock serial port. (1-30) -X, --rts-cts Enable RTS/CTS on the serial port. -x, --xon-xoff Enable XON/XOFF on the serial port. -Y , --retries= Retry failed communications with inverter up to times (1-100) -y, --rpt-retries Report the number of retires done *** Required Parameters *** -a , --address= Inverter address. 1-31 on older inverters, 1-63 on newer inverters. Device Serial Device.
Commenta