Interessante dove sarebbe sta scheda? L'impianto è partito a sett. 2011.
Questa è la scheda di cui parlavo.
saluti
aurora -f -b --address=2 /dev/ttyUSB0 szttyDevice: /dev/ttyUSB0 yDelay: 1 yTimeout 0 mS yMaxRunTime ~ devLCKfile: devLCKfileNew: Got Params RunTime 20150318-18:36:54 v1.8.8 Endian : Little tm_gmtoff : no PID : 2830 Attempting to get lock on Serial Port /dev/ttyUSB0... Checking for lock Checking process 2830 for lock rPID: 2830 SubStrPos: aurora command: aurora = me Appears we got the lock. Opening Serial Port /dev/ttyUSB0... Serial Port /dev/ttyUSB0 successfully opened. Configuring serial device... Flushing unread data first... Success! Flushing serial device buffer... Success! Comm Check: Let's see if the Aurora is listening... Elapsed time since last comm 0 us Attempt 1 Clearing read buffer Success! szSerBufferSave OK! 02 3a 00 00 00 00 00 00 00 00 command: 02 3a 00 00 00 00 00 00 01 b7 Flushing serial device buffer... Success! Sending command... sent 10 characters Draining serial device buffer... Success! Cleared data buffer: 00 00 00 00 00 00 00 00 00 00 Read char #1 RC=1 (00) waited/max 57060/1000000 uS Read char #2 RC=1 (06) waited/max 16/1000000 uS Read char #3 RC=1 (31) waited/max 11/1000000 uS Read char #4 RC=1 (49) waited/max 1003/1000000 uS Read char #5 RC=1 (4e) waited/max 15/1000000 uS Read char #6 RC=1 (4e) waited/max 1138/1000000 uS Read char #7 RC=1 (3a) waited/max 15/1000000 uS Read char #8 RC=1 (71) waited/max 12/1000000 uS answer: 00 06 31 49 4e 4e 3a 71 received 8 characters CRC receive OK 713a Transmission State Check: 0 Model ID "1" qMultiplier -1.0000000 -- PVI-3.0-OUTD -- Comm Check: OK Elapsed time since last comm 130 us Attempt 1 Clearing read buffer Success! szSerBufferSave OK! 02 48 00 00 00 00 00 00 00 00 command: 02 48 00 00 00 00 00 00 f6 91 Flushing serial device buffer... Success! Sending command... sent 10 characters Draining serial device buffer... Success! Cleared data buffer: 00 00 00 00 00 00 00 00 00 00 Read char #1 RC=1 (00) waited/max 2668/1000000 uS Read char #2 RC=1 (06) waited/max 15/1000000 uS Read char #3 RC=1 (43) waited/max 1209/1000000 uS Read char #4 RC=1 (30) waited/max 15/1000000 uS Read char #5 RC=1 (32) waited/max 10/1000000 uS Read char #6 RC=1 (31) waited/max 1058/1000000 uS Read char #7 RC=1 (db) waited/max 17/1000000 uS Read char #8 RC=1 (dc) waited/max 1188/1000000 uS answer: 00 06 43 30 32 31 db dc received 8 characters CRC receive OK dcdb Transmission State Check: 0 Firmware: C.0.2.1 Complete. rc: 0 Restoring Serial Port settings /dev/ttyUSB0... Success! Flushing serial device buffer... Success! Closing Serial Port /dev/ttyUSB0... Success! devLCKfile: devLCKfileNew: Clearing Serial Port Lock (2830)... done. Complete 20150318-18:36:54
aurora -f -b --address=2 /dev/ttyUSB0 szttyDevice: /dev/ttyUSB0 yDelay: 1 yTimeout 0 mS yMaxRunTime ~ devLCKfile: devLCKfileNew: Got Params RunTime 20150318-18:39:18 v1.8.8 Endian : Little tm_gmtoff : no PID : 2838 Attempting to get lock on Serial Port /dev/ttyUSB0... Checking for lock Checking process 2838 for lock rPID: 2838 SubStrPos: aurora command: aurora = me Appears we got the lock. Opening Serial Port /dev/ttyUSB0... Serial Port /dev/ttyUSB0 successfully opened. Configuring serial device... Flushing unread data first... Success! Flushing serial device buffer... Success! Comm Check: Let's see if the Aurora is listening... Elapsed time since last comm 0 us Attempt 1 Clearing read buffer Success! szSerBufferSave OK! 02 3a 00 00 00 00 00 00 00 00 command: 02 3a 00 00 00 00 00 00 01 b7 Flushing serial device buffer... Success! Sending command... sent 10 characters Draining serial device buffer... Success! Cleared data buffer: 00 00 00 00 00 00 00 00 00 00 Read char #1 RC=1 (00) waited/max 3628/1000000 uS Read char #2 RC=1 (06) waited/max 1293/1000000 uS Read char #3 RC=1 (31) waited/max 15/1000000 uS Read char #4 RC=1 (49) waited/max 10/1000000 uS Read char #5 RC=1 (4e) waited/max 1119/1000000 uS Read char #6 RC=1 (4e) waited/max 16/1000000 uS Read char #7 RC=1 (3a) waited/max 11/1000000 uS Read char #8 RC=1 (71) waited/max 1044/1000000 uS answer: 00 06 31 49 4e 4e 3a 71 received 8 characters CRC receive OK 713a Transmission State Check: 0 Model ID "1" qMultiplier -1.0000000 -- PVI-3.0-OUTD -- Comm Check: OK Elapsed time since last comm 325 us Attempt 1 Clearing read buffer Success! szSerBufferSave OK! 02 48 00 00 00 00 00 00 00 00 command: 02 48 00 00 00 00 00 00 f6 91 Flushing serial device buffer... Success! Sending command... sent 10 characters Draining serial device buffer... Success! Cleared data buffer: 00 00 00 00 00 00 00 00 00 00 Read char #1 RC=1 (db) waited/max 1325/1000000 uS Read char #2 RC=1 (dc) waited/max 14/1000000 uS Read char #3 RC=0 (00) waited/max 97594/1000000 uS answer: Got -1 characters Restoring Serial Port settings /dev/ttyUSB0... Success! Flushing serial device buffer... Success! Closing Serial Port /dev/ttyUSB0... Success! devLCKfile: devLCKfileNew: Clearing Serial Port Lock (2838)... done. 20150318-18:39:18: aurora: ERROR: Received bad return code (-1 72) Complete 20150318-18:39:18
Commenta