sdm120c 1.3.5.1: ModBus RTU client to read EASTRON SDM120C smart mini power meter registersCopyright (C) 2015 Gianfranco Di PrinzioComplied with libmodbus 3.0.3 Usage: sdm120c-td [-a address] [-d] [-x] [-p] [-v] [-c] [-e] [-i] [-t] [-f] [-g] [-T] [[-m]|[-q]] [-b baud_rate] [-P parity] [-S bit] [-z num_retries] [-j seconds] [-w seconds] [-1 | -2] device sdm120c-td [-a address] [-d] [-x] [-b baud_rate] [-P parity] [-S bit] [-1 | -2] [-z num_retries] [-j seconds] [-w seconds] -s new_address device sdm120c-td [-a address] [-d] [-x] [-b baud_rate] [-P parity] [-S bit] [-1 | -2] [-z num_retries] [-j seconds] [-w seconds] -r baud_rate device sdm120c-td [-a address] [-d] [-x] [-b baud_rate] [-P parity] [-S bit] [-1 | -2] [-z num_retries] [-j seconds] [-w seconds] -R new_time device Required: device Serial device (i.e. /dev/ttyUSB0) Connection parameters: -a address Meter number (1-247). Default: 1 -b baud_rate Use baud_rate serial port speed (1200, 2400, 4800, 9600) Default: 2400 -P parity Use parity (E, N, O) -S bit Use stop bits (1, 2). Default: 1 -1 Model: SDM120C (default) -2 Model: SDM220 Reading parameters (no parameter = retrieves all values): -p Get power (W) -v Get voltage (V) -c Get current (A) -l Get apparent power (VA) -n Get reactive power (VAR) -f Get frequency (Hz) -o Get phase angle (Degree) -g Get power factor -i Get imported energy (Wh) -e Get exported energy (Wh) -t Get total energy (Wh) -A Get imported reactive energy (VARh) -B Get exported reactive energy (VARh) -C Get total reactive energy (VARh) -T Get Time for rotating display values (0=no rotation) -m Output values in IEC 62056 format ID(VALUE*UNIT) -q Output values in compact mode Writing new settings parameters: -s new_address Set new meter number (1-247) -r baud_rate Set baud_rate meter speed (1200, 2400, 4800, 9600) -N parity Set parity and stop bits (0-3) 0: N1, 1: E1, 2: O1, 3:N2 -R new_time Set rotation time for displaying values (0=no rotation) SDM120: (0-30s) SDM120: (m-m-s-m) Demand interval, Slide time, Scroll time, Backlight time -M new_mmode Set total energy measurement mode (1-3) 1: Total=Import, 2: Total=Import+Export, 3: Total=Import-Export Fine tuning & debug parameters: -z num_retries Try to read max num_retries times on bus before exiting with error. Default: 1 (no retry) -j 1/10 secs Response timeout. Default: 2=0.2s -D 1/1000 secs Delay before sending commands. Default: 0ms -w seconds Time to wait to lock serial port (1-30s). Default: 0s -W 1/1000 secs Time to wait for 485 line to settle. Default: 0ms -y 1/1000 secs Set timeout between every bytes (1-500). Default: disabled -d debug_level Debug (0=disable, 1=debug, 2=errors to syslog, 3=both) Default: Fatal errors to syslog + fatal errors to stderr -x Trace (libmodbus debug on)
$output = shell_exec('pkill -f pooler485 > /dev/null 2>&1');
$output = shell_exec('pkill -f pooler485 > /dev/null 2>&1 &');
Commenta